ILC - International Linear Collider

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

survey:damping_rings [2006/10/25 00:37] (current)
s_a created
Line 1: Line 1:
 +Alignment errors are assumed to be randomly Gaussian
 +distributed within 2 sigma. A set of nominal alignment
 +tolerances, in both transverse planes and as rotations
 +about the s-axis, are given in Table 1.
 +
 +
 +Table 1 Alignment Tolerance
 +
 +              Δx (μm)   Δy (μm)  ΔΨ (mrad)
 +
 +  * Quadrupole    30        30        0.3
 +  * Sextupole     30        30        0.3
 +  * BPM          100       100       20
  
 
survey/damping_rings.txt · Last modified: 2006/10/25 00:37 by s_a
 